ProfiLux 4 Programming Guide
EN 2017-02-06 37
etc.
Random – Using a random generator, all, some or none of the pumps belonging to this group
are activated in a continuous random variation. The time until the switching state changes
again can be set (see beneath).
4.5.2.2 Assign Pumps
Here you can define which pumps belong to this group. A pump must not be assigned to
several groups.
4.5.2.3 Tide Duration
In the modes Sequence, Surge or Random you can set the time after which the switch on state
of the pumps shall change again. Enter a Minimal and a Maximal tide duration.
The time after a new switch-on state is to be assumed is determined by random-number
generator in the range of these two times.
Shall the time be always the same, the same value must be entered for Minimal and Maximal
tide duration.
The Minimal and a Maximal tide duration is adjustable between 1 second and 8 hours.
If a switching socket is to control the corresponding flow pump, the time
period must not be too small - otherwise too frequent switching can lead to
damage to the socket or the pump!
4.5.2.4 Wave
The type of wave generation can be set individually for each group: