12. ALARMS
To increase safety levels in operating the flatwork ironer and to protect the main elements in the process, the
microprocessor has the capacity to detect the presence of the most significant malfunctions if they should by
any chance occur. An audible warning is automatically activated once the alarm is triggered.
Once an alarm is detected, press the key . The display will show the report corresponding to the alarm.
Press the key to cancel the alarm.
For AGA machines only:
Once an alarm is detected, press the key . The display will show the report corresponding to the alarm.
Press the key to cancel the alarm.
In the case of an alarm associated with the burner, the burner control LED will remain red. To cancel the alarm,
press the burner control button for two seconds and then press the button on the display to cancel the
alarm.
Whilst the malfunction persists the alarm cannot possibly be cancelled.
CAUTION!
Procedure in the event of an alarm
Any procedure aimed at rectifying the fault provoking an alarm that involves removing the protection covers has
to be performed by the Customer’s Technical Assistance Service or by the Authorised Technical Assistance
Service, and never by the user of the machine.
Never carry out an intervention that is not described in this section.
DANGER!
BEFORE COMMENCING ANY PROCEDURE WHICH INVOLVES REMOVING THE PROTECTION COVERS:
DISCONNECT AND MECHANICALLY LOCK THE MACHINE’S SWITCH BREAKER.
CLOSE AND MECHANICALLY LOCK THE MANUAL VALVES FOR THE SOURCES OF HEATING.
WAIT A MINIMUM OF FIVE MINUTES TO ELIMINATE THE RISK OF ANY RESIDUAL VOLTAGE AND TO
ENSURE THERE ARE NO MOVING PARTS.
CHECK THAT WITH TEMPERATURE OF THE MACHINE THERE RUNS NO RISK TO CARRYING OUT
THE PROCEDURES.
12.1. List of main alarms:
PB/PBP51, X20
1.- EMERGENCY STOP
PB32, X13
ALM / EMER
Emergency Stop button activated
Probable cause:
Emergency Stop activated
Procedure:
Release the Emergency Stop button.
Press: the STOP key and next the START key to start the machine.
If fault persists, disconnect the power supply and close the manual gas inlet valve (machines heated with gas).
Contact Authorised Technical Services.