Steps for the connection 66
Code no. 550038
Rev. no. 16/1018
5.3.4. Radiant burner. Changing the type of gas
Changing the type of fuel gas requires changing the combustion adjustment elements: the injector, burner
adjustment and fume suction adjustment.
Remove the covers from the corresponding base-
frames.
Remove the junction (A) between the burner and the
premixing fan and replace the existing injector (B) with
and injector that is suitable for the new type of gas (Fig.
5.11).
Consult injector values in the table in Section 4.3.2 and
4.4.2.
Fit the junction between the burner and the fan.
Fig. 5.11
Adjust the solenoid valve (Measurement A in Figure
5.12) in accordance with the data in the tables in
Section 4.3.2 and 4.4.2.
Fig. 5.12