4.4. AGA certified models. Specific values for models with GAS heating
Consult the description of the burner in Section 1.2.
VERY IMPORTANT
NOTES RELATING TO POWER AND GAS DETAILS
Volumetric consumptions and massic consumption. Values calculated at 15ºC (59ºF); 1013 mbar (14.7
PSI).
ATMOSPHERIC BURNER. AGA Models
Combustible gases circuit:
type B14 in accordance with EN1020
(Append. B)
Nominal calorie cons.
with regard to H
i
Nominal calorie cons.
with regard to H
s
Nominal calorie cons.
with regard to H
i
Nominal calorie cons.
with regard to H
s
4.4.1. Maximum NOx values and classification
Maximum NOx values obtained and corrected in accordance with EN1020:2009:
- For 2nd family gases (G20 and G25): 127 mg/kWh. Class 3.
- For 3rd family gases (G31): 155 mg/kWh. Class 2.
4.4.2. Categories of commercially available gases
(Summary of the B1 & B4 tables taken from the EN437:2003+A1:2009 standards)