60 3A6748B
3. Install clamp on pump cylinder. Torque
clamp to 100in-lb (11.3 Nm).
4. Install clamp on intake housing. Torque
clamp to 100in-lb (11.3 Nm).
5. Refer to Pump Installation, page 56, to
install pump.
Pump Repair 6912
Disassembly
NOTE: It may be easier to leave the pump
connected to the connecting rod and bearing
housing if the only assembies to be cleaned
and inspected are the intake housing or
piston valve.
1. Perform Pressure Relief Procedure,
page 19. Unplug power cord to
disconnect power.
2. Refer to Pump Removal, page 54, to
remove pump.
3. Remove clamp and intake housing.
4. Disassemble intake valve.