CE6000-UM-251-9370 8-2
8 SERVICE MODES
(7) Press the F1 key (SENSOR & KEY TEST). The following menu is displayed.
YHOME=: “H” is displayed when the Y home sensor dog is crossed to the Y home sensor.
P_ROL=: “H” is displayed when the push roller sensor dog is crossed to the push roller sensor.
CAM=: “H” is displayed when the cam sensor dog is crossed to the cam sensor.
XFRONT=: “H” is displayed when the X front media sensor is covered by the media.
XREAR=: “H” is displayed when the X rear media sensor is covered by the media.
1=: “H” is displayed when the F1 key is pressed.
2=: “H” is displayed when the F2 key is pressed.
3=: “H” is displayed when the F3 key is pressed.
4=: “H” is displayed when the F4 key is pressed.
Sim=: “H” is displayed when the SIMPLE key is pressed.
Pau=: “H” is displayed when the PAUSE/MENU key is pressed.
Up=: “H” is displayed when the UP arrow key is pressed.
Lf=: “H” is displayed when the LEFT arrow key is pressed.
Ri=: “H” is displayed when the RIGHT arrow key is pressed.
Dn=: “H” is displayed when the DOWN arrow key is pressed.
Fas=: “H” is displayed when the FAST key is pressed.
Ori=: “H” is displayed when the ORIGIN key is pressed.
Cop=: “H” is displayed when the COPY key is pressed.
Cod=: “H” is displayed when the CONDITION key is pressed.
Ent=: “H” is displayed when the ENTER key is pressed.
(8) When testing is complete, turn off the power to the plotter.