CE6000-UM-251-9370 8-1
8 SERVICE MODES
8 SERVICE MODES
8.1 Sensor and Key switch test Mode
This mode checks the sensor status. If there is a bad sensor you will observe one of the symptoms in the
table below.
Please check the relevant sensor(s).
Sensor Symptom
Y home sensor The pen block hits the right side plate.
Cam sensor The plotter displays “LOAD MEDIA!” when media is already loaded.
Push roller sensor The pen block hits the left side plate.
+X, -X media sensor Media drops out of the plotter.
If there is a bad switch on panel you can check at this mode.
How to test the sensors
(1) Load an A4 size sheet of paper into the plotter.
(2) Turn on the power while pressing the FAST and ENTER keys.
(3) Select the Language and the Length Unit if the Language selection menu is displayed (See section
7.5.).
(4) Press the PAUSE/MENU key at the following menu.
(5) The following menu is displayed, and then press the right arrow key (ADJ).
(6) The following menu is displayed.