CE6000-UM-251-9370 9-4
9 TROUBLESHOOTING
9.4 Error Messages in GP-GL Command Mode
Error
Code
LCD Display Cause Solution
E02001
The plotter received an
unrecognizable
Press the [ENTER] key.
Noise came in when the computer
was turned on.
Configure to drive the plotter from
the menu of the software.
The software configuration
regarding the output device has
been changed.
Reset the interface settings of the
plotter.
The plotter’s interface conditions
have changed.
Reset the interface settings of the
plotter.
E02004
A command was received
containing numeric parameters
that exceed that command’s
permissible range.
Configure to drive the plotter from
the menu of the software.
The software configuration
regarding the output device has
been changed.
Reset the interface settings of the
software.
The plotter’s interface conditions
have changed.
Reset the interface settings of the
plotter.
E02005
An error occurred in the receipt of
data within the interface.
Configure to drive the plotter from
the menu of the software.
The software configuration
regarding the output device has
been changed.
Reset the interface settings of the
software.
The plotter’s interface conditions
have changed.
Reset the interface settings of the
plotter.
E02006
The data out of cutting range has
been received.
Check the data.
Check the size of media and the
cutting range.
Check the magnification setting.
Check the step size settings.