CE6000-UM-251-9370 7-1
7 ELECTRICAL ADJUSTMENTS
7 ELECTRICAL ADJUSTMENTS
7.1 DIP Switch Settings
Factory presets (Normal Mode)
Dip Switch 1 2 3 4 Model
SW1
1234
ON
OFF
OFF OFF OFF OFF
CE6000-40
Old Grid Roller (Right side grid roller width 150 mm)
SW1
1234
ON
OFF
OFF OFF ON OFF
CE6000-40/CE6000-40 PLUS
New Grid Roller (Right side grid roller width 160 mm)
SW1
1234
ON
OFF
ON OFF OFF OFF
CE6000-60
CE6000-60 PLUS
SW1
1234
ON
OFF
OFF ON OFF OFF
CE6000-120/AMO
CE6000-120PLUS
SW1
1234
ON
OFF
ON ON OFF OFF CE6000-120AP
Note: Perform the NOV-RAM Clear before this dip switch setting when the Model setting was changed.
NOV-RAM Clear
Dip Switch 1 2 3 4 Model
SW1
1234
ON
OFF
OFF OFF OFF ON
CE6000-40
CE6000-40 PLUS
SW1
1234
ON
OFF
ON OFF OFF ON
CE6000-60
CE6000-60 PLUS
SW1
1234
ON
OFF
OFF ON OFF ON
CE6000-120
CE6000-120 PLUS
SW1
1234
ON
OFF
ON ON OFF ON CE6000-120AP

Table of Contents