CE6000-UM-251-9370 9-5
9 TROUBLESHOOTING
9.5 Error Messages in HP-GL Command Mode
Error
Code
LCD Display Cause Solution
E03001
An unrecognizable instruction was
executed.
Execute a recognizable command.
Did the plotter receive an
unrecognizable command?
Send correct data to plotter.
Is there any noise on the line?
Check the interface cable or move
the plotter to another location.
Has the correct model name been
set for the plotter?
Set the correct model name.
Configure your software
application menu to permit
Graphtec plotter control. Re-
specify the software application’s
interface conditions.
E03002
A command was executed with
the wrong number of parameters.
Execute the command with the
correct number of parameters.
Configure your software
application menu to permit
Graphtec plotter control. Re-
specify the software application’s
interface conditions. Set the
correct model name if it was
incorrect.
E03003
A command containing an
unusable parameter was
specified.
Execute the command with its
parameters specified within their
permissible ranges.
Configure your software
application menu to permit
Graphtec plotter control. Re-
specify the software application’s
interface conditions. Set the
correct model name if it was
incorrect.
E03005
An unrecognizable character set
was specified.
Specify a recognizable character
set.
Configure your software
application menu to permit
Graphtec plotter control. Re-
specify the software application’s
interface conditions. Set the
correct model name if it was
incorrect.
E03006
The data being input exceeds the
capacity of the plotter’s
Execute coordinates within the
cutting area.
E03007
Coordinates of command
specified out of cutting area.
Adjust the buffer size.
E03010
Other output command was
executed while executing an
output command.
Check the program.
E03 011
An invalid byte was received after
ESC code.
Check the program.