CE6000-UM-251-9370 6-30
6 DISASSEMBLY AND REASSEMBLY
How to reinstall the Y-exible cable
(1) Clean the surface of the Y-rail with alcohol to remove any glue from the double-sided adhesive
tape that was attached the Y-exible cable.
(2) Afx two pieces of double-sided adhesive tape to the exible cable guide of the Y-rail. The rst
piece of tape should start at the right end of the Y-rail. The position of the second piece of tape
depends on the model.
Size of the double-sided adhesive tape:
10 mm wide, 20 mm long for the rst piece of tape (Nitto #5000NS)
10 mm wide, 50 mm long for the second piece of tape (Nitto #5000NS)
Position of the second piece of tape:
CE6000-40: 240 mm from the right end of the Y-rail
CE6000-60: 330 mm from the right end of the Y-rail
CE6000-120/AMO/AP: 650 mm from the right end of the Y-rail
The rst piece of double-sided adhesive tape.
Afx the tape onto the right edge of the Y-rail.
The second piece of double-sided adhesive tape.
Afx the tape at the specied position on the Y-rail.
(3) Insert the Y-exible cable into the core and connect the Y-exible cable onto the Y relay board.
(4) Attach the core to the Y-relay board using double-sided adhesive tape.
(5) Attach the exible cable clamper to hold the Y-exible cable and the core on the Y-relay board.
(6) Move the pen block to the left end.