TRIGGERS
The second spike on the graph was
captured with a Normal power
profile setting. The green arrow
shows when the tool was turned on,
the orange arrow indicates when
GRIT checks whether the tool is
pulling power above the set
Activation Level.
When a slow start motor is not configured with a Delay Power Profile, the system
immediately measures the current after the trigger is unlocked. Because of the time it
takes a slow start motor to ramp up to full speed, the system misses the accurate
information that the tool is running.
This would impact not only the system turning on an associated collector or opening
associated blast gates, but would impact the system's ability to initiate an Emergency
Lock, if needed.