TRIGGERS
The Advanced power profile setting is for finetuning how the trigger operates. If
none of the other preset settings accurately capture the tool's specific power
startup timing/levels, you can set all of them manually in Advanced. This will show
three new settings: Activation Delay, Deactivation Delay and Unlock Measurement
Delay.
Two machines that frequently require "Advanced" power profiles are CNC
machines and Lasers.
Advanced
1. The Activation Delay setting controls how long the trigger needs to sense the
current flowing before the attached device/tool is considered running. This setting
is used when a tool such as a CNC machine might cause a current spike when the
gantry moves, but this should not send out the messages to open gates and turn on
the collector. Only when the current level sensed is above the Activation Level
setting
and for the amount of time specified here, should the tool be considered
running. The same applies for how long the tool needs to be without current to be
considered off. The system uses this to understand when to turn on an associated
collector, air quality device, and move associated gates.