TRIGGERS
Although the Tablesaw has a power spike when the trigger is unlocked, it does not need to
be configured with a Spike power profile because the inrush spike level is still less than
when the saw is actually running. Configure this trigger with a Normal power profile and
increase the Activation Level to 1.5 Amps (higher than the computer spike but lower than
the consistent current draw when the saw is running).
Saw's computer
turns on and
spikes to .5 A
Saw is turned on
and the motor
spikes to 27 A
Saw's power
stabilizes at ~5 A