8.3.6 Internal mechanical error E5
The red LED flashes every 5 seconds. The FlexxPump stops operating.
Malfunction Cause Measure
Internal mechani-
cal error E5
Mechanical error Carry out a special dispens-
ing Ü262
If unsuccessful: Send
FlexxPump to Güdel for in-
spection or repair.
Table8-5 Internal mechanical error E5
Fix the mechanical fault as follows:
1 Switch off FlexxPump ÜChapter6.6,272
2 Switch on the FlexxPump Ü2101
3 Carry out a special dispensing Ü262
3.1 If fault message E5 reoccurs immediately: Send FlexxPump to
Güdel for inspection or repair.
3.2 If FlexxPump works without another fault message E5: No other
action required.
The mechanical fault has been corrected.
8.3.7 System malfunction
In case of system malfunctions, switch the device off and on again. This does
not delete the data memory.
Fix system malfunctions as follows:
1 Switch off FlexxPump
1.1 Touch the active surface with the magnetic peg
1.2 Wait for LED to flash 3x
1.3 Remove magnetic peg
(Display switches to "OFF")
2 Switch on the FlexxPump Ü261
The system malfunctions are fixed.
Repairs
OPERATING MANUAL Automatic lubrication system
FlexxPump 402 / 402B
90071992656444683_v9.0_EN-US