3.3.1.3 Temperature ranges
The following temperature ranges and humidity apply:
Product life phase Temperature range Air humidity
Transport -10 to +60 °C
Operation -20 to +70 °C Up to and at 85 %,
condensation forma-
tion is not permissible
Storage -10 to +40 °C Up to 75 %
Table3-2 Temperature ranges: FlexxPump
The temperature has an effect on the battery charge:
Temperatures above 40°C cause irreversible self-discharge or failure of the
battery
Temperatures below 20°C reversibly lower the battery charge, but may
cause the battery to fail in exceptional cases
3.3.1.4 IP protection class
The product conforms to the protection class IP65.
3.3.1.5 Operating pressure
The operating pressure is 70 bar and is monitored electronically by counter-
pressure measurement.