EasyManua.ls Logo

GUDEL FlexxPump 402 - Cycle; Setting the Lubrication; Table 6-4 Lubrication Cycle: Factory Settings for P1; Table 6-5 Lubrication Cycle: Factory Settings for P2

Default Icon
156 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6.4.4 Setting the lubrication cycle
The lubrication cycle is set as follows by default:
Setting Value
Emptying time of the cartridge P1 12 months
Table6-4 Lubrication cycle: Factory settings for P1
Entire system Value
3 lubrication points (e.g. EP, TMF,
TMO)
3
6 lubrication points (e.g. ZP) 4
4 lubrication points (e.g. X-axis FP) 3
Table6-5 Lubrication cycle: Factory settings for P2
WARNING
Automatic startup
During work on the product, there is danger of the machine starting up auto-
matically. This can lead to severe or fatal injuries!
Before working in the danger area:
Secure vertical axes (if equipped) against falling.
Switch off the superordinate main power supply. Secure it against being
switched on again (main switch for the complete system)
Before switching on the system again, make sure that no one is in the dan-
ger area
The ON indicator flashes only briefly. If you do not touch the active surface
with the magnetic pin during this time, then the FlexxPump automatically
starts a lubrication cycle. In this case, cycle the FlexxPump off and back on.
Operation
OPERATING MANUAL Automatic lubrication system
FlexxPump 402 / 402B