9.3 Decommissioning
9.3.1 Shutdown
WARNING
Falling axes, workpieces
Falling axes or workpieces can cause physical damage, serious or fatal injuries!
Set down any workpieces before working in the danger area
Never enter the area below suspended axes and workpieces
Secure suspended axes using the stipulated equipment
Check the belts of the telescope axes for signs of breakage and tears
Do not empty the lubrication lines and the gearbox when shutting down the
product.
To shut down the product, proceed as follows:
1 Switch off FlexxPump
2 Remove cartridge
3 Cut the power supply (connecting cable for pump type 402; plug of the
battery for pump type 402B)
The product has been shut down.
9.3.2 Cleaning, rust-proofing
Clean away any dirt and dust from the product. Clean the product thor-
oughly. Dispose of any cloths soaked in oil or grease in an environmentally
friendly manner. Ü2117
Apply corrosion protection to all bright parts.
9.3.3 Identification
Label the product with the following data:
Date of decommissioning
Internal machine number/name
Additional data as per internal guidelines
Decommissioning, storage
OPERATING MANUAL Automatic lubrication system
FlexxPump 402 / 402B
90071992656444683_v9.0_EN-US
113

Table of Contents