Digit display
The digit display serves for communication.
LED
The LED indicates the function:
The green and red LEDs glow for 5 seconds after activation to check their
own status
The green LED glows during the lubrication cycle
The green LED flashes if there is no error
The red LED flashes every 5 seconds if there is an error
Fault message
The fault message shows the type of error. More detailed information
Ü2106
4.2.2.4 Control elements
The magnetic peg is magnetic and integrated into the vent locking mechanism.
Remove the vent locking mechanism to use the magnetic peg. Touch the ac-
tive surface with it to perform the following actions:
Switch the FlexxPump on and off
Set lubrication cycle
Perform functional check
D003499
A
C B
Fig.4-5 Magnetic peg
A Vent locking mechanism
B Active surface
C Magnetic peg
Design, function