6.4.2 Lubrication quantity
The effective lubrication quantity dispensed in a defined period depends on
two settings:
Emptying time P1 of the cartridge
Lubrication quantity P2
The lubrication quantity P2 defines the lubrication quantity per cycle and out-
let. You can set a value between 1 and 30. With the value at 1, the lubrication
quantity per outlet is 0.15 cm
3
. Increasing the value by 1 increases the lubrica-
tion quantity per outlet by 0.15 cm
3
.
0,15 cm
0,3 cm
0,45 cm
0,15 cm
0,3 cm
0,45 cm
0,15 cm
0,3 cm
0,45 cm
P
2
= 1
P
2
= 2
P
2
= 3
P
2
= …
D003863
Fig.6-1 Lubrication quantity P2