EasyManua.ls Logo

GW Instek GDM-8351 - Configure:current:ac; Configure:current:dcac; Configure:fresistance; Configure:resistance

GW Instek GDM-8351
159 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
COMMAND OVERVIEW
109
CONFigure:CURRent:AC
Sets measurement to AC Current on the first display and
specifies the range.
Parameter: [None] | [Range(<NRf> | MIN | MAX | DEF)]
Example: CONF:CURR:AC 10e-2
Sets the measurement mode to ACI with a 100mA range.
CONFigure:CURRent:DCAC
Sets measurement to DC+AC Current on the first display and
specifies the range.
Parameter: [None] | [Range(<NRf> | MIN | MAX | DEF)]
Example: CONF:CURR:DCAC 10e-2
Sets the measurement mode to DC+AC Current with a 100mA
range.
CONFigure:RESistance
Sets measurement to 2W Resistance on the first display and
specifies range.
Parameter: [None] | [Range(<NRf> | MIN | MAX | DEF)]
Example: CONF:RES 10e3
Sets the range to 10k.
CONFigure:FRESistance
Sets measurement to 4W Resistance on the first display and
specifies range.
Parameter: [None] | [Range(<NRf> | MIN | MAX | DEF)]
Example: CONF:FRES 10e3
Sets the range to 10k.