Example
Below shows the data associated with an SPI event
table in a spreadsheet.
Time MOSI MISO
-11.60us 0D87 0D87
-10.16us 06C0 06C0
-8.720us 8343 343
-7.282us 243 243
-5.840us 0C88 0C88
Adding a Label to a Bus
Background
A Label can be added to the buses. This label will
appear next to the bus indicator on the left hand-
side of the display.
Panel Operation
1. To add a label to the bus, press Edit
Labels from the Bus menu.
2. To choose a preset label, Press User
Preset from the side menu and
choose a label.
Labels
ACK, AD0, ADDR, ANALOG,
BIT, CAS, CLK, CLOCK, CLR,
COUNT, DATA, DTACK,
ENABLE, HALT, INT, IN, IRQ,
LATCH, LOAD, NMI
Edit Label
3. Press Edit Character to edit the
current label.