EasyManua.ls Logo

GW Instek MSO-2000EA - Common

GW Instek MSO-2000EA
351 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MSO-2000E & 2000EA User Manual
340
Common
Vertical
Sensitivity
Resolution
8 bit
:1mV*~10V/div
*: When the vertical scale is set to
1mV/div, the bandwidth limit will be set
to 20MHz automatically.
Input Coupling
AC, DC, GND
Input Impedance
1MΩ// 16pF approx.
DC Gain Accuracy*
1mV: ±5% full scale
2mV: ±3% full scale
Polarity
Normal & Invert
Maximum Input
Voltage
300Vrms, CAT I
Offset Position Range
1mV/div ~ 20mV/div : ±0.5V
50mV/div ~ 200mV/div : ±5V
500mV/div ~ 2V/div : ±25V
5V/div ~ 10V/div : ±250V
Waveform Signal
Process
+, -, ×, ÷, FFT, FFTrms, User Defined
Expression
FFT: Spectral magnitude. Set FFT Vertical
Scale to Linear RMS or dBV RMS, and
FFT Window to Rectangular, Hamming,
Hanning, or Blackman-Harris.
Trigger
Source
CH1, CH2, CH3*, CH4*, Line, EXT**,
D0-D15
*four channel models only.
**two channel models only.
Trigger Mode
Auto (supports Roll Mode for 100 ms/div
and slower), Normal, Single Sequence
Trigger Type
Edge, Pulse Width(Glitch), Video, Pulse
Runt, Rise & Fall(Slope), Timeout,
Alternate, Event-Delay(1~65535 events),
Time-Delay(Duration, 4nS~10S), Bus
Holdoff range
4nS to 10S
Coupling
AC, DC, LF rej., Hf rej., Noise rej.
Sensitivity
1div
External
Trigger
Range
±15V
Sensitivity
DC ~ 100MHz Approx. 100mV
100MHz ~ 200MHz Approx. 150mV
Input Impedance
1MΩ±3%~16pF
Horizontal
Time base Range
1ns/div ~ 100s/div (1-2-5 increments)
ROLL: 100ms/div ~ 100s/div
Pre-trigger
10 div maximum

Table of Contents

Related product manuals