EasyManua.ls Logo

GW Instek MSO-2000EA - Trigger

GW Instek MSO-2000EA
351 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MSO-2000E & 2000EA User Manual
148
Trigger
The trigger configures the conditions for when the MSO-
2000E/2000EA captures a waveform.
Trigger Type Overview
Edge
The edge trigger is the simplest trigger type. An
edge trigger triggers when the signal crosses an
amplitude threshold with either a positive or
negative slope.
Rising edge trigger
Falling edge trigger
Delay
The Delay trigger works in tandem with the edge
trigger, by waiting for a specified time (duration)
or number of events before the delay trigger starts.
This method allows pinpointing a location in a
long series of trigger events.
Note: when using the delay trigger, the edge trigger
source can be any one of the channel inputs, the EXT*
input or the AC line.
*EXT is only available on 2 channel models.
Delay trigger example (by event)
1 2 3
A
B
C
D
A
Edge trigger
B
Delay Source
C
Delay event count (3)
D
First triggering point