MSO-2000E & 2000EA User Manual
216
Analog Waveform
Background
The analog waveform function combines the
digital channel inputs into two 8-bit analog
waveforms. The analog waveforms are created
from the digital channel groups D0~7 and D8~15.
Example
Panel Operation
1. Press the Option key.
Option
2. Press the Analog Waveform key.
3. Press Select and choose between
Wave_A1 (D7~D0) or Wave_A2
(D15~D8).
Display on Screen
4. Press Display to display the
selected waveforms on the screen.
Set Vertical
Position
5. Press Vertical until the div
parameter is highlighted. Use the
Variable knob to set the position.