14. The oscilloscope will now trigger when the
specified bus data matches the Trigger When
conditions.
LIN Bus Trigger
The LIN bus trigger conditions can be set at any time after the bus
setting has been set to LIN.
Panel Operation
1. Set the Bus to LIN in the bus menu.
Page 133
2. Press the Trigger Menu key.
Menu
3. Press Type from the bottom menu.
4. Select Others Bus from
the side menu. The Bus
indicator appears at the
bottom of the display.
From left: Bus trigger, Trigger source
5. Press Trigger On and select the
triggering condition for the
selected bus.
Trigger On
Sync, Identifier, Data, Id and Data,
Wakeup Frame, Sleep Frame, Error.
Trigger On
Identifier
6. If Identifier or Id & Data was
configured for the Trigger On
setting, press Identifier from the
bottom menu.