Go-NoGo application
Background
The Go-NoGo test checks if a waveform fits inside
a user-specified maximum and minimum
boundary. Boundary templates are automatically
created from a source channel. Boundary
tolerances and violation conditions can be set.
Choose the Go_NoGo application
from the APP menu. See page 257.
Set Go-NoGo
Conditions
Select the Go-NoGo conditions (NG When) and
actions when a Go-NoGo condition has been met
(Violating).
1. Press NG When from the bottom
menu and select the NoGo
conditions:
Enter: Sets the NoGo condition to
when the input signal stays within
the limit boundary.
Exit: Sets the NoGo condition to
when the input signal exceeds the
limit boundary.