ADVANCED CONFIGURATION
135
7. Press Configure from the bottom
menu.
8. From the side menu select configuration items.
1.2kbps, 2.4kbps, 4.8kbps,
9.6kbps, 10.417kbps, 19.2kbps
Include Parity
Bits with Id
Parallel Bus
The digital channels can be configured as a parallel bus. The
number of bits that defines the bus as well as which bit is used as
the bus clock can also be configured. The trigger should also be set
to parallel bus. Please see page 184.
The read data can be displayed as binary, hexadecimal or ASCII.
An event table can also be created to aid in debugging.
1. Connect each of the parallel bus signals
(variable length can be configured) to the
oscilloscope’s digital channels. Connect the
ground potential to the ground connector of the
Digital card.
bit2
bit3
bit4
GND
bit1
G
1
2
3
4
Digital