EasyManua.ls Logo

Haulotte HTT13 - Electrocution Hazards

Haulotte HTT13
110 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
14 4000670450 E 04.19 USA / GB
3632T - HTT13
A
- Foreword
2.1.4 - Electrocution Hazards
The machine is not electrically insulated and does not provide protection from contact or
proximity to electrically charged conductors.
Always position the lift at a safe distance from electrically charged conductors to ensure that
no part of the machine is within an unsafe area.
Respect the local rules and the minimum safety distance from power lines.
Minimum safe approach distances
N.B.-:-U
SE THIS TABLE EXCEPT WHERE LOCAL REGULATIONS INDICATE OTHERWISE.
Electric voltage Minimum safety distance
Mètre Feet
0 - 300 V Avoid contact
300 V - 50 kV 3 10
50 - 200 kV 5 15
200 - 350 kV 6 20
350 - 500 kV 8 25
500 - 750 kV 11 35
750 - 1000 kV 14 45
Do not operate the machine when close to live power lines, consider
the movement of the machine and the sway of the electric power
lines particularly in windy conditions.
Do not operate the machine during lightning, thunderstorms, snow/
ice or any weather condition that could compromise operator safety.
Do not use the machine as a ground for welding.
Do not weld on the machine without first disconnecting the battery
terminals.
Always disconnect ground cable first.
The machine must not be used while charging the batteries.
When using the AC power supply, ensure it is protected with a circuit
breaker and residual current device.
Keep away from the machine if it contacts energized power lines.
Personnel on the ground or in the platform must not touch or operate
the machine until energized power lines are shut off.