9 3D Touch Probes
L
9.3 Measuring Workpieces with a 3D Touch Probe
.
The angle between the angle reference axis and the side of the workpiece appears as the ROTATION ANGLE in
the BASIC ROTATION function.
I
I
Cancel the basic rotation.
-----------------------------------
Restore the previous basic rotation by setting the ROTATION ANGLE to the value that you wrote down
1
To measure the angle between two sides of a workpiece:
L
L
Fig.
9.14:
Measuring the angle between two
sides of a workpiece
Select the probe function for compensating workpiece misalignment.
If you will need the current basic rotation later, write down the value that appears under ROTATION ANGLE.
I
Make a basic rotation for the first side (see “Compensating workpiece misalignment”).
Probe the second side as for a basic rotation, but do not set the ROTATION ANGLE to zero!
i
I
The angle PA between the workpiece sides appears as the ROTATION ANGLE in the BASIC ROTATION func-
tion.
I
Cancel the basic rotation.
~~~~~ -~--
Restore the previous basic rotation by setting the ROTATION ANGLE to the value that you wrote down
previously.
J