EasyManua.ls Logo

Hioki LR8402-20 - Chapter 11 Specifications

Hioki LR8402-20
298 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operating Precautions
11
Connecting to the Pulse Input, Alarm Output, and Other External Control Terminals
The External Control Terminals is not isolated from the HiLogger’s
chassis ground. Make certain that there will be no potential differ-
ence between the External Control Terminals and the ground of any
connected device. Otherwise, the HiLogger or device could be dam-
aged.
To avoid electric shock or damage to the equipment, always
observe the following precautions when connecting to pulse input
terminals, alarm output terminals, and External Control Terminals.
Always turn off the power to the HiLogger and to any devices to be
connected before making connections.
Be careful to avoid exceeding the ratings of External Control Termi-
nals.
Ensure that devices and systems to be connected to the External
Control Terminals are properly isolated.
Using a CF Card/USB flash drive
Inserting a CF card/USB flash drive upside down, backwards or in the wrong
direction may damage the CF card, USB flash drive, or HiLogger.
Never eject a CF card /USB flash drive while measuring or when the
HiLogge
r is or accessing the card. Data on the CF card/USB flash drive
may be destroyed. (The CF icon/USB flash drive icon at the lower left is
red while the card is being accessed.)
Do not transport the HiLogger while a USB flash drive is connected.
D
amage could result.
As the CF card/USB flash drive is sensitive to static electricity, damage to
the CF card/USB flash dr
ive or wrong operations by the HiLogger may
occur due to static electricity. Please be careful when handling it.
With some USB flash drives, the HiLogger may not start up if power is
turn
ed on while the USB flash drive is inserted. In such a case, turn
power on first, and then insert the USB flash drive. It is recommended to
try out operation with a USB flash drive before starting to use it for actual
measurements.
The Flash memory in a CF card/USB flash drive has a limited operating
life. After long-term usage, data storage and retrieval become difficult. In
this case, replace the CF card/USB flash drive with a new one.
We cannot provide compensation for data loss in a CF card/USB flash
drive, regardless of content or cause of the damage. Data is also cleared
from memory if a long time passes after measuring. Always maintain a
backup of important data stored on a CF card/USB flash drive.
Although real-time saving to USB flash drive is supported, a CF card is
reco
mmended for data preservation. Performance cannot be guaranteed
when using storage media other than a Hioki-specified CF card option.