Operation Diagnostics
Basic - L3P
Release
3.1
06/07
9.1
Sending traps
167
9.1.1 SNMP trap listing
All possible traps that can occur are listed in the following table.
Trap description Meaning
authenticationFailure is sent if a station attempts to access an agent without
permission.
coldStart is sent for a cold and warm start during the boot process
after successful management initialization.
hmAutoconfigAdapterTrap is sent when the ACA AutoConfiguration Adapter is
inserted or removed.
linkDown is sent if the link to a port is interrupted.
linkUp is sent if the link to a port is re-established.
hmTemperature is sent if the temperature exceeds the limit set.
hmPowerSupply is sent if the status of the voltage supply changes.
hmSigConRelayChange is sent if the status of the signal contact changes.
newRoot is sent if the sending agent becomes the new root of the
spanning tree.
topologyChange is sent if the transmission mode of a port changes.
risingAlarm is sent if an RMON alarm input exceeds the upper
threshold.
fallingAlarm is sent if an RMON alarm input falls below the lower
threshold.
hmPortSecurityTrap is sent if a MAC address is detected at the port which does
not correspond to the current settings of:
hmPortSecPermission and
hmPorSecAction set either to trapOnly (2) or
portDisable (3)
hmModuleMapChange is sent, if the hardware configuration has changed.
hmBPDUGuardTrap is sent if a BPDU is received at a port although the BPDU
guard function is activated.
hmMrpReconfig is sent if the configuration of the MRP ring changes.
hmRingRedReconfig is sent if the configuration of the HIPER ring changes.
hmRingRedCplReconfig is sent if the configuration of the redundant ring/network
coupling changes.
hmSNTPTrap is sent if errors occur in connection with the SNTP protocol
(e.g. server not available).
hmRelayDuplicateTrap is sent if a duplicate IP address is detected in connection
with the DHCP Option 82.
lldpRemTablesChangeTrap is sent if an entry in the topology table changes.
vrrpTrapNewMaster is sent if an other router has become master for an inter-
face or a virtual address.
vrrpTrapAuthFailure is sent, if the router receives a frame with invalid authenti-
cation from an other vrrp router.
Table 12: Possible traps

Table of Contents

Other manuals for Hirschmann Power MICE

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hirschmann Power MICE and is the answer not in the manual?

Hirschmann Power MICE Specifications

General IconGeneral
BrandHirschmann
ModelPower MICE
CategoryNetwork Router
LanguageEnglish

Related product manuals