5 Control System
146
SMGB0087 rev.0 - 12/2013
Pressing
RUN/STOP
switch
STOP
Power to
indoor unit:
OFF
Power to
outdoor unit:
OFF
LCD indication: OFF
Power to PCB in indoor unit: OFF
from 1
Pressing
AUTO-LOUVER switch
Stop the
AUTO-LOUVER
Start the
AUTO-LOUVER
Alternatively
only for air panel
or indoor unit with
auto-louver
Power to CMC: OFF
RUN/STOP lamp: OFF
COOL, set fan speed and setting temperature
indication: continuously ON
Power to PCB in outdoor unit: OFF
Power to CH: OFF
Stop of inverter
Stop of MC
Tem-
perature on
the top of comp.
Power to CH: ON
Power to CH: OFF
(for RAS-(2-2.5)HVNP and
RAS-3HVNC < 60ºC)
< Td target temperature -15ºC
(for RAS-(2-2.5)HVNP and
RAS-3HVNC ≥ 60ºC)
≥ Td target temperature -10ºC
Power to Y52C or RY1: ON
Stop of MOF
Power to MIF: OFF
After
1 min, 20 sec.
Power to YH2: OFF
Yes
No
MD: OFF
Power to EHW:
OFF
(for unit with drain pump)
(for unit with EHW)
IU: Indoor unit
OU: Outdoor unit