10 Servicing
397
SMGB0087 rev.0 - 12/2013
10
10.5.16 Removing other electrical components
1 Remove the service cover following “10.5.1Removingservicecover”in this chapter.
2 Open the P plate turning counter clockwise approximately 90° following “10.5.9Openingelectricalbox(P-Mounting
Plate)”.
• Check that the LED201 (red) on Inverter is OFF when the P plate is opened.
Capacitors
1 Remove all the wiring connected to the capacitors.
N O T E
Thewireshavepolarcharacters.Identifythewiremark
bandandtheindicationonthecapacitorwhenconnec-
tingwires.
2 Remove 3 screws xing each capacitor.
CMC
1 Remove all the wiring connected to CMC.
2 Remove 2 screws xing the CMC.
Reactor
1 Remove 4 screws xing the reactor.
Noise lter
1 Remove all the wiring connected to the noise lter.
2 Hold the upper part of the 6 holders with the long
nose pliers and remove the noise lter.
Holder
Long-Nose Pliers
Noise Filter
Holder
Noise lter
Long nose pliers
N O T E
Whenmountingcomponents,besuretomatchthewiring
connectionswiththemarkbandcodes.
Fuses
Noise lter
Reactor
CMC
Inverter
Capacitors
Diode