Table 24 DkuTempMaxInfo.csv
î ´le (Title: <<DB temperature maximum value
Information>>)
Item Description
Date Year, month, and date when temperature
data was acquir
ed in the format:
YYYY/MM/DD hh:mm:ss
DB00 DBPS001
Temperature maximum value
Maximum temperature (°C) for the two-
hour period of DB00 DBPS001
DB47 DBPS472
Temperature maximum value
Maximum temperature (°C) for the two-
hour period of DB47 DBPS472
For VSP G200, item shows up to DB07
DBPS072.
For VSP G400, VSP G600, VSP F400, VSP
F600, item shows up to DB23 DBPS232.
Note: An item name is displayed as DBxx DBPSxxy. The names ar
e listed in ascending
order of the DB number. See
DkuTempInfo.csv (on page 248) for locations and values for
DBxx and DBPSxxy
.
DkuTempMinInfo.csv
This CSV î ´le contains information about DB temperature for every two hours. A record is
DB temper
ature information obtained from the environment monitor. A record output to
the î ´rst line shows the latest temperature information. Because DB temperature
information is measured by DBPS, items are displayed in this unit*.
DkuTempMinInfo.csv shows the minimum temperature as DB temperature data. The
total number of items depends on the following model:
â–
VSP G200: 17
â–
VSP G400/VSP G600/VSP F400/VSP F600: 49
â–
VSP G800/VSP F800: 97
The DB temperature data displayed in DkuTempAveInfo.csv (average temperature only),
DkuTempMaxInfo.csv (maximum temperature only), and DkuTempMinInfo.csv (minimum
temperature only) is the same value as the DB temperature data for DkuTempInfo.csv.
If the system is in maintenance mode or the SVP is rebooted, the data that is output
every two hours might not contain data for the period. If a failure occurs in the storage
system, the correct information might not be output.
DkuTempMinInfo.csv
Appendix A: Examples of storage conî ´guration reports
System Administrator Guide for VSP Gx00 models and VSP Fx00 models 251