Item Content
Package Type Type of CHB to which a port of the local storage system connecting to the
e
xternal storage system belongs
■
Fibre: 8FC4 (CHB), 16FC2 (CHB), 32FC4R (CHB)
■
iSCSI: 10iSCSI2o (CHB), 10iSCSI2c (CHB)
IP Address IP address for an iSCSI target of an external storage system
■
IPv6:
XXXX:XXXX:XXXX:XXXX:XXXX:XXXX:XXXX:XXXX (hexadecimal)
■
IPv4:
XXX.XXX.XXX.XXX (decimal)
■
Blank if "Package Type" is iSCSI.
TCP Port Number TCP port number (1 through 65535) for the iSCSI target of an external
storage system
Blank if "Package Type" is Fibre.
iSCSI Target Name iSCSI target name of an external storage system
Blank if "Package Type" is Fibre.
Notes:
1. If the character string contains a comma, the comma is converted to a tab.
EnvMonInfo.csv
This CSV le contains information about the power and temperature of the storage
system. Po
wer and temperature measurements from the environment monitor are
recorded every two hours.
No records are created during a system power failure or if the breakers are turned o. If
the system is in maintenance mode or the SVP is rebooted, up to two hours of records
could be lost.
If a failure occurs in the storage system, the correct information might not be output.
Table 28 EnvMonInfo.csv le (Title: <<Electric power and temperature
Information>>)
Item Description
Date Year, month, and date when record data was acquired for the two-hour
period in the format:
YYYY/MM/DD HH:MM:SS
Electric power average Average value of electric power (W)
EnvMonInfo.csv
Appendix A: Examples of storage
conguration reports
System Administrator Guide for VSP Gx00 models and VSP Fx00 models 255