Mode Category Description Default MCU/RCU
122 ShadowImage For Split or Resync request from the Mainframe host
and
Storage Navigator.
Mode 122 = ON: By specifying Split or Resync,
Steady/Quick Split or Normal/Quick Resync is
respectively executed in accordance with Normal/
Quick setting.
Mode 122 = OFF (default): By specifying Split or
Resync, Steady/Quick Split or Normal/Quick Resync is
respectively executed in accordance with Normal/
Quick setting.
For details about pairsplit/pairresync command
behavior, contact customer support (see SOM122
sheet).
Notes:
1. Executing the pairresync command from CCI
may be related to the SOM 87 setting.
2. When performing At-Time Split from CCI, set this
SOM to OFF, or specify the environment variable
HORCC_SPLT for Quick. Otherwise, Pairsplit may
turn timeout.
3. This SOM becomes eective after specifying
Split/Resync following the mode setting. The
mode function does not work if it is set during
the Split/Resync operation.
OFF -
System option modes
Appendix B: System option modes
System Administrator Guide for VSP Gx00 models and VSP Fx00 models 290

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hitachi VSP Gx00 series and is the answer not in the manual?

Hitachi VSP Gx00 series Specifications

General IconGeneral
BrandHitachi
ModelVSP Gx00 series
CategoryStorage
LanguageEnglish

Related product manuals