Installing components 27
2.
Install power supply blanks in any unused power supply bay.
Populating power supply bays
For AC redundant (N+N power supplies) configurations, an even number of power supplies is required. For
this configuration, where N is the number of power supplies being used, populate the power supply bays as
shown.
N + N Populate the following power supply bays
1 + 1
1 and 4
2 + 2
1, 2, 4, and 5
3 + 3
Populate all bays
For power supply redundant (N+1 power supplies) configurations, where N is the number of power supplies
being used, populate the power supply bays as shown.
N + 1 Populate the following power supply bays
1 + 1
1 and 4
2 + 1
1, 4, and 2
3 + 1
1, 4, 2, and 5
4 + 1
1, 4, 2, 5, and 3
5 + 1
Populate all bays
Installing a full-height blade
The enclosure ships with device bay shelves to support half-height devices. To install a full-height device,
remove the device bay shelf and the corresponding blanks.
To install a full-height blade:
1. Remove the blank.
2. Remove the three adjacent blanks.
3. Remove the device bay shelf.