Interface Access and System Information
Interface Access: Console/Serial Link, Web, and Inbound Telnet
Outbound Telnet to Another Device. This feature operates indepen-
dently of the telnet-server status and enables you to Telnet to another device
that has an IP address.
Syntax: telnet < ip-address >
For example:
ProCurve # telnet 10.28.27.204
Reconfigure Web Browser Access. In the default configuration, web
browser access is enabled.
Syntax: [no] web-management
To disable web browser access:
ProCurve(config)# no web-management
To re-enable web browser access:
ProCurve(config)# web-management
Reconfigure the Console/Serial Link Settings. You can reconfigure one
or more console parameters with one console command.
Syntax: console
[terminal < vt100 | ansi | none >]
[screen-refresh < 1 | 3 | 5 | 10 | 20 | 30 | 45 | 60 >]
[baud-rate
< speed-sense | 1200 | 2400 | 4800 | 9600 | 19200 |38400 | 57600 |
1155200 >]
[ flow-control < xon/xoff | none >]
[inactivity-timer < 0 | 1 | 5 | 10 | 15 | 20 | 30 | 60 |120 >]
[events <none | all | non-info | critical | debug]
[local-terminal <vt 100 | none | ansi>]