Redundancy (Switch 8212zl)
Event Log Messages
Event Log Messages
# System Message Severity Description
62 Mgmt module [1 or 2] went down
without saving crash information
info The specified management module went down
without saving the crash information.
RMON_BOOT_NO_CRASH_RECORD
63 Mgmt module [1 or 2] went down info The specified management module was rebooted.
RMON_BOOT_CRASH_RECORD0
260 Mgmt Module [1 or 2] Active info The specified management module is the active
management module
RMON_SYSTEM_MGMT_MOD_ACTIVE
261 Mgmt Module [1 or 2] in Standby Mode info The specified management module is in standby
mode.
RMON_SYSTEM_MGMT_MOD_STANDBY
262 Mgmt Module [1 or 2] Failed -
Synchronization Failed
warn Synchronization failed on the indicated
management module.
RMON_SYSTEM_MGMT_FAILED_SYNC
263 Mgmt Module [1 or 2] Offline
(redundancy disabled)
info The no redundancy management-module
command was issued and the specified
management module went offline.
RMON_SYSTEM_MGMT_OFFLINE
264 Mgmt Module [1 or 2] Failed Selftest warn The specified management module failed selftest
and will not become an active or standby module.
RMON_SYSTEM_MGMT_FAILED
265 Lost Communication with Mgmt Module
[1 or 2]
warn A management module failed to receive heartbeats
from the other management module.
RMON_SYSTEM_MGMT_LOST_COMM
266 Resetting Mgmt Module [1 or 2] info The specified management module is being reset.
This can occur if you perform a boot standby
command or for other reasons when an individual
module is rebooted.
RMON_SYSTEM_MGMT_RESET
267 Mgmt Module [1 or 2] - Running
different version of SW
info The specified management module is running a
different version of software from the other
management module.
RMON_SYSTEM_MGMT_OS_DIFF
15-46