Redundancy (Switch 8212zl)
Event Log Messages
# System Message Severity Description
268 Mgmt Module [1 or 2] - Failover
occurred
warn A switchover occurred because of a hardware or
software failure or because the management
module reset button was pressed.
RMON_SYSTEM_MGMT_FAILOVER
269 Mgmt Module [1 or 2] - User initiated
switchover occurred
info The user has initiated switchover using the
redundancy switchover command so that the other
management module can become the active
management module.
RMON_SYSTEM_MGMT_SWITCHOVER
270 Mgmt Module [1 or 2] - Offline
(incompatible SW versions)
warn The software version in the specified management
module is not compatible with the other module and
it has gone offline.
RMON_SYSTEM_MGMT_INCOMPAT_OS
271 Other management module is not in
standby, shutdown request ignored
warn A shutdown request is ignored because the
standby module is not in standby mode. A
management module must be in active or standby
mode to be shut down. The module goes into a
“down” state which allows you to safely swap it
out.
RMON_SYSTEM_MGMT_HSBUTTONERR
272 Mgmt Module [1 or 2] Offline
(shutdown)
info The specified management module is offline
because of a shutdown.
RMON_SYSTEM_MGMT_SHUTDOWN
273 Resetting Mgmt Module [1 or 2] <reason
for reset>
info The indicated management module is being reset
for the reason displayed.
RMON_SYSTEM_MGMT_RESET_REASON
537 Syncing [primary |secondary] OS to
standby [started | completed]
info This message is logged when the OS begins
synchronizing to the standby module. It displays the
status of the synchronization.
RMON_SYSTEM_OS_SYNC
538 Standby <boot image | default boot>
updated, rebooting standby
info This message is logged when the standby’s
management module boot image is overwritten,
requiring a reboot.
RMON_SYSTEM_STANDBY_REBOOT
539 Initial active to standby sync <started |
completed>
info Indicates the beginning or end of the initial
synchronization of the active management
module’s flash image to the standby management
module.
RMON_SYSTEM_INITIAL_SYNC