untagged
Port Status and Configuration
Uni-Directional Link Detection (UDLD)
To display summary information on all UDLD-enabled ports, enter the show
link-keepalive command. For example:
ProCurve(config)# show link-keepalive
Total link-keepalive enabled ports: 4
Port 5 has been disabled by
the System Administrator.
Keepalive Retries: 3 Keepalive Interval: 1 sec
Port Enabled Physical Keepalive Adjacent UDLD
Status Status Switch VLAN
-------------------------------------------------------------------
1 Yes up up 00d9d-f9b700 200
2 Yes up up 01560-7b1600
3 Yes down off-line
4 Yes up failure
5 No down off-line
Port 4 is connected, but is blocked
due to a link-keepalive failure
Port 1 is UDLD-enabled, and
tagged for a specific VLAN.
Port 3 is UDLD-enabled, but
has no physical connection.
Figure 10-20. Example of Show Link-Keepalive Command