Redundancy (Switch 8212zl)
Downloading a New Software Version
ProCurve(config)# show version
Management Module 1: Active
Image stamp: /sw/code/build/btm(t2g)
Mar 15 2007 12:28:32
K.12.29
64
Boot Image: Primary
Management Module 2: Standby
Image stamp: /sw/code/build/btm(t2g)
Mismatch exists
Mar 21 2007 14:24:38
K.12.30
789
Boot Image: Secondary
ProCurve(config)# show redundancy
Settings
------- -
Mgmt Redundancy : Enabled
Statistics
--------- -
Failovers : 0
Last Failover :
Slot Module Description Status SW Version Boot Image
MM1 ProCurve J9092A Management Module 8200zl Active K.12.30 Primary
MM2 ProCurve J9092A Management Module 8200zl Standby K.12.30 Primary
FM1 ProCurve J9093A Fabric Module 8200zl Enabled
FM2 ProCurve J9093A Fabric Module 8200zl Enabled
Warning: Standby module is running a different software version. Configuration
changes on active management module may not take effect on a failover. See “show
version”.
Figure 15-11. Example of a Software Version Mismatch Between the Active and Standby Modules
15-20