Event
code
Message text and description Details and solution
2069 Initialization failure due to barcode
reader error.
Check the event log for additional events
that provide more specific information.
Run the robotic test.
Verify that all cartridges have high-quality
proper barcode labels and that the labels are
properly applied.
Verify that the library is running the latest
firmware version. If not, update the library
firmware.
Power cycle the library and see if the issue
persists.
2070 Inventory scan failed because of
elevator axis problem.
Check for obstructions, such as a cartridge
sticking out, in the vertical pathway of the
robotics assembly.
Clear any obstructions from the bottom of
the library.
Check the event log for additional events
that provide more specific information.
Verify that the robotic assembly is level
within the module. If the module was
recently moved or the robotic assembly
replaced, the assembly could be out of
alignment.
Check to see if the locking mechanism in the
robotic assembly is engaged. If so, move the
robotics assembly to the fully locked
position.
Table Continued