Event
code
Message text and description Details and solution
2076 I2C bus signals invalid.
1. Remove all tape drives from the affected
module and then reboot the library.
If the problem persists, the cause is likely to
be in the module.
2. Reinstall one drive after another, rebooting
after each one.
3. If the problem comes back, the cause could
be in the drive that was most recently added
or in the drive slot.
Try a different drive in the drive slot and then
try the suspect drive in a different slot to see
which part is causing the problem.
4. If the problem appears to be with the tape
drive, use the RMI to pull a drive support
ticket and check the device analysis section.
L&TT must be installed to view a support
ticket.
2077 Failed to store calibration data to
chassis.
Power cycle the library.
2078 The library firmware currently installed
does not support the installed robotics
assembly type.
The installed robotics assembly has an
alternate motor encoder implementation, which
is not supported by the installed library
firmware.
2079 Could not upgrade barcode reader
firmware.
1. Reboot the library.
2. If the error persists, see if the event log
shows events related to the spooling
mechanism or robotic assembly.
Table Continued