huawei(config-if-vlanif8)#ip address 192.168.50.1 24
huawei(config-if-vlanif8)#quit
3. Add the cascading port to the management VLAN.
huawei(config)#port vlan 8 0/3 0
4. Check whether the management channel between the OLT and the ONU is available.
– Run the ping 192.168.50.2 command on the OLT to check the connectivity
between the OLT and the ONU. If the OLT can receive Internet Control Message
Protocol (ICMP) ECHO-REPLY packets sent from the ONU, the ONU is
connected to the OLT.
– If you can remotely log in to the ONU from the OLT for configuration, the ONU
is connected to the OLT.
l Configure a management channel if the remote software commissioning using GE upstream
transmission is disabled and the cascading board is OPGD.
1. Configure the inband management VLAN and IP address of the ONU.
Log in to the ONU through a local serial port and configure the ONU as follows: The
ID of the inband management VLAN is 8 and the management IP address is
192.168.50.2/24.
huawei(config)#vlan 8 smart
huawei(config)#port vlan 8 0/0 0
huawei(config)#interface vlanif 8
huawei(config-if-vlanif8)#ip address 192.168.50.2 24
huawei(config-if-vlanif8)#quit
2. Configure the inband management VLAN and IP address of the OLT.
The ID of the inband management VLAN is 8, the VLAN priority is 6, and the
management IP address is 192.168.50.1/24.
huawei(config)#vlan 8 smart
huawei(config)#port vlan 8 0/19 0
huawei(config)#vlan priority 8 6
huawei(config)#interface vlanif 8
huawei(config-if-vlanif8)#ip address 192.168.50.1 24
huawei(config-if-vlanif8)#quit
3. Configure the inband management service flow.
The index of the service flow is 1. The ID of the management VLAN is 8. The Ethernet
cascading port is 0/2/0. The ID of the user-side VLAN is 8. The OLT does not limit
the rate of the inband management service flow. Therefore, use the default traffic
profile with ID 6, which does not limit the rate of a service flow.
huawei(config)#service-port 1 vlan 8 eth 0/2/0 multi-service user-vlan 8
rx-cttr 6 tx-cttr 6
4. Check whether the management channel between the OLT and the ONU is available.
– Run the ping 192.168.50.2 command on the OLT to check the connectivity
between the OLT and the ONU. If the OLT can receive ICMP ECHO-REPLY
packets sent from the ONU, the ONU is connected to the OLT.
– If you can remotely log in to the ONU from the OLT for configuration, the ONU
is connected to the OLT.
----End
SmartAX MA5600T/MA5603T/MA5608T Multi-service
Access Module
Commissioning and Configuration Guide
11 FTTB and FTTC Solution Configuration
Issue 01 (2014-04-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
1031