Add ONUs to the OLT and
configure the management
service port
Configure the TDM
connection and TDM PW
Start
Verify services
End
Configure the congestion
control policy and security
policy
Configure clock
synchronization
Configure network
protection
OLT-A/B
OLT-A/B
OLT-A/B
OLT-A/B
OLT-A/B
/ONU
14.4.4.3 Adding ONUs to the OLT and Configuring the Management Service Port
Related configurations can be performed for ONUs only after the ONUs are successfully added
to the OLT. After the inband management service port is created and available, you can log in
to the ONUs from the OLT to configure the ONUs.
Context
l When an ONU is added, related profiles need to be bound to the ONU, including the
dynamic bandwidth allocation (DBA) profile, line profile, and alarm profile.
l An ONU can be added in two modes: adding an ONU offline and confirming an ONU
online. Select either mode as required.
SmartAX MA5600T/MA5603T/MA5608T Multi-service
Access Module
Commissioning and Configuration Guide 14 FTTM Configuration (Base Station Access)
Issue 01 (2014-04-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
1451

Table of Contents

Other manuals for Huawei SmartAX MA5600T

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei SmartAX MA5600T and is the answer not in the manual?

Huawei SmartAX MA5600T Specifications

General IconGeneral
BrandHuawei
ModelSmartAX MA5600T
CategoryControl Unit
LanguageEnglish

Related product manuals