EasyManuals Logo

Huawei SmartAX MA5600T User Manual

Huawei SmartAX MA5600T
1979 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #1380 background imageLoading...
Page #1380 background image
NOTE
You can also create a SAToP connection by configuring the MAC address statically. If the remote MAC address
(the MAC address of the EDTB board on the OLT) is 0800-3E32-5310, create a SAToP connection in static
mode as follows:
huawei(config)#cesop-connect tdm 10 vlan 300 local-udp 50048 remote-mac
0800-3E32-5310 remote-ip 10.10.50.10 remote-udp 50048
Step 4 (Optional) Configure attributes of the SAToP connection.
NOTE
The attributes of the SAToP connection on the OLT must be consistent with those on the ONU. Generally, use
the system default values.
l Run the cesop rtp command to configure whether the SAToP packet carries the RTP header.
The SAToP packet carries the RTP header by default.
l Run the cesop encap command to configure SSRC, payload type, and SN of the SAToP
packet. The default value of these parameters is 0.
l Run the cesop jitter-buffer command to configure the buffer depth of the SAToP packet.
The default buffer depth is 2000 μs.
l Run the cesop loadtime command to configure the load time of the SAToP packet. The
default load time is 125 μs.
l Run the cesop priority command to configure the priority of the SAToP packet. The default
priority is 7.
----End
13.3.6.8 Configuring Clock Synchronization
Context
Configuration concept for clock synchronization:
1. OLT_A traces the upstream E1/T1 line clock of the EDTB board as the system clock.
2. OLT_B Obtains the system clock by GICK/X2CS boards in synchronous Ethernet mode.
3. The ONU uses the line clock of the GPON upstream port as the system clock.
4. The Tx clock of ONU is synchronized to the system clock of the ONU.
Data Plan
System
clock
Clock source Description
OLT_A E1/T1 line clock: 0/5/0 OLT_A Obtains E1/STM-1 line clock from SDH as
the system clock. and then transmits it to the
cascading OLT_B over GE/10GE interface.
OLT_B Synchronous ethernet
line clock: 0/19/0
OLT_B Obtains the system clock in synchronous
Ethernet mode. The clock is transmitted to the ONU
over the GPON line.
ONU GPON line clock: 0/0/1 ONU uses the line clock of the GPON upstream port
as the system clock.
SmartAX MA5600T/MA5603T/MA5608T Multi-service
Access Module
Commissioning and Configuration Guide 13 FTTO Configuration (Large-sized Enterprise Access)
Issue 01 (2014-04-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
1355

Table of Contents

Other manuals for Huawei SmartAX MA5600T

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei SmartAX MA5600T and is the answer not in the manual?

Huawei SmartAX MA5600T Specifications

General IconGeneral
BrandHuawei
ModelSmartAX MA5600T
CategoryControl Unit
LanguageEnglish

Related product manuals