Table 3-13 Data plan for configuring TDM SHDSL for carrying the PRA service
Item Data
Clock source E1 line clock on port 0/3/0
SHDSL port Port ID: 0/3/16
IUA link set
parameter
IUA link set ID 1
Working mode of a
link set
override
Pending time 10s
Mode of generating
the interface ID
2
Whether the link in
the link set supports
the interlocking
enable
Service
environment
corresponding to the
IUA link set
client
IUA link parameter IUA link ID 15
Local port ID 1401
Local IP address 10.13.4.116/16 (It must exist in the signaling IP
address pool.)
Remote port ID 1400
IP address of the
primary MGC
10.14.1.2/16 (IP address of the primary MGC)
MGC that is bound
to the IUA link
primary-mgc
Priority of the IUA
link
3
IP address of the
primary MGC
10.14.1.2/16 (IP address of the primary MGC)
PRA user interface data MGID: 0
IUA link set ID: 0
Terminal ID: 0
Prerequisite
l The H802EDTB board must be in position and must work in the normal state.
SmartAX MA5600T/MA5603T/MA5608T Multi-service
Access Module
Commissioning and Configuration Guide
3 Configuring the DSLAM Services
Issue 01 (2014-04-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
347

Table of Contents

Other manuals for Huawei SmartAX MA5600T

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei SmartAX MA5600T and is the answer not in the manual?

Huawei SmartAX MA5600T Specifications

General IconGeneral
BrandHuawei
ModelSmartAX MA5600T
CategoryControl Unit
LanguageEnglish

Related product manuals