e. After the configuration is completed, run the commit command to make the
configured parameters take effect.
huawei(config-gpon-lineprofile-10)#commit
huawei(config-gpon-lineprofile-10)#quit
3. (Optional) Add an alarm profile.
l The ID of the default GPON alarm profile is 1. The thresholds for all the alarm
parameters in the default alarm profile are 0, which indicates that no alarm is generated.
l In this example, the default alarm profile is used and therefore the configuration of the
alarm profile is not required.
Step 2 Add an ONU to an OLT.
Assume that the ID of GPON port 0/2/1 is 1, SN is 32303131B39FD641, management mode is
SNMP, and the bound line profile is fttb(c). Connect the ONU to such a GPON port through the
optical splitter.
There are two modes to add an ONT: add an ONT offline and confirm an automatically
discovered ONU.
l Add an ONU offline.
huawei(config)#interface gpon 0/2
huawei(config-if-gpon-0/2)#ont add 1 ontid 1 sn-auth 32303131B39FD641
snmp ont-lineprofile-name fttb(c)
l Confirm an automatically discovered ONU.
huawei(config)#interface gpon 0/2
huawei(config-if-gpon-0/2)#port 1 ont-auto-find enable
huawei(config-if-gpon-0/2)#display ont autofind 1
huawei(config-if-gpon-0/2)#ont confirm 1 ontid 1 sn-auth 32303131B39FD641
snmp ont-lineprofile-name fttb(c)
1. (Optional) Bind the alarm profile to the ONU.
By default, alarm profile 1 automatically bound to an ONU. A non-default alarm profile is
bound manually only when the default one does not meet the requirement.
In this example, default alarm profile 1 is used and therefore the configuration of the alarm
profile is not required.
Step 3 Check the ONU status.
After an ONU is added, run the display ont info command to query the current status of the
ONU. Ensure that Config flag of the ONU is active, Run State is online, and Config state is
normal.
huawei(config-if-gpon-0/2)#display ont info 1 1
---------------------------------------------------------------------
F/S/P : 0/2/1
ONT-ID : 1
Control flag : active //The ONU is activated.
Run state : online //The ONU is online.
Config state : normal //The ONU configurations are recovered
normally.
...//The rest of the response information is not provided here.
huawei(config-if-gpon-0/2)#quit
----End
Follow-up Procedure
When Config state is failed, Run state is offline, or Match state is mismatch:
SmartAX MA5600T/MA5603T/MA5608T Multi-service
Access Module
Commissioning and Configuration Guide
11 FTTB and FTTC Solution Configuration
Issue 01 (2014-04-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
887

Table of Contents

Other manuals for Huawei SmartAX MA5600T

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei SmartAX MA5600T and is the answer not in the manual?

Huawei SmartAX MA5600T Specifications

General IconGeneral
BrandHuawei
ModelSmartAX MA5600T
CategoryControl Unit
LanguageEnglish

Related product manuals